MACsec Layer 2 Security in HSR Rings in Substation Automation Systems
dc.contributor.author | Lázaro Arrotegui, Jesús | |
dc.contributor.author | Astarloa Cuéllar, Armando Fermín | |
dc.contributor.author | Araujo Parra, José Ángel | |
dc.contributor.author | Moreira Ciruelos, Naiara | |
dc.contributor.author | Bidarte Peraita, Unai | |
dc.date.accessioned | 2018-12-14T18:53:50Z | |
dc.date.available | 2018-12-14T18:53:50Z | |
dc.date.issued | 2017-01-31 | |
dc.identifier.citation | Energies 10(2) : (2017) // Article ID 162 | es_ES |
dc.identifier.issn | 1996-1073 | |
dc.identifier.uri | http://hdl.handle.net/10810/30386 | |
dc.description.abstract | The smart-grid concept takes the communications from the enclosed and protected environment of a substation to the wider city or nationwide area. In this environment, cyber security takes a key role in order to secure the communications. The challenge is to be able to secure the grid without impacting the latency while, at the same time, maintaining compatibility with older devices and non secure services. At the lower level, added security must not interfere with the redundancy and the latency required for the real-time substation automation communications. This paper studies how to integrate IEEE MAC Security standard (MACsec) in the substation environment, especially when used in substation system communications that have stringent response time requirements and zero recovery time as defined in IEC 62439-3. | es_ES |
dc.description.sponsorship | This work has been supported by the Ministerio de Economia y Competitividad of Spain within the project TEC2014-53785-R, and it has been carried out inside the Research and Education Unit UFI11/16 of the UPV/EHU and partially supported by the Basque Government within the funds for research groups of the Basque University system IT978-16 and within the project TFactory ER-2014/0016. In addition, FEDER funds and UPV/EHU Ph.D. scholarship funding are acknowledged. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | MDPI | es_ES |
dc.relation | info:eu-repo/grantAgreement/MINECO/TEC2014-53785-R | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es/ | * |
dc.subject | smart-grid | es_ES |
dc.subject | industrial communication | es_ES |
dc.subject | substation automation | es_ES |
dc.subject | cryptography | es_ES |
dc.title | MACsec Layer 2 Security in HSR Rings in Substation Automation Systems | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.holder | © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/). | es_ES |
dc.rights.holder | Atribución 3.0 España | * |
dc.relation.publisherversion | https://www.mdpi.com/1996-1073/10/2/162 | es_ES |
dc.identifier.doi | 10.3390/en10020162 | |
dc.departamentoes | Tecnología electrónica | es_ES |
dc.departamentoeu | Teknologia elektronikoa | es_ES |
Files in this item
This item appears in the following Collection(s)
Except where otherwise noted, this item's license is described as © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).