dc.contributor.author | Aramendia Iradi, Iñigo | |
dc.contributor.author | Fernández Gámiz, Unai | |
dc.contributor.author | López Arraiza, Alberto | |
dc.contributor.author | Rey Santano, María Carmen | |
dc.contributor.author | Mielgo, Victoria | |
dc.contributor.author | Basterrechea Elguezabal, Francisco José | |
dc.contributor.author | Sancho Saiz, Javier | |
dc.contributor.author | Gómez Solaeche, Miguel Ángel | |
dc.date.accessioned | 2019-01-21T08:09:08Z | |
dc.date.available | 2019-01-21T08:09:08Z | |
dc.date.issued | 2019-01-05 | |
dc.identifier.citation | Pharmaceutics 11(1) : (2019) // Article ID 19 | es_ES |
dc.identifier.issn | 1999-4923 | |
dc.identifier.uri | http://hdl.handle.net/10810/31064 | |
dc.description.abstract | The potential of non-invasive ventilation procedures and new minimally invasive techniques has resulted in the research of alternative approaches as the aerosolization for the treatment of respiratory distress syndrome (RDS). The aim of this work was to design two nebulizer prototypes and to evaluate them studying the particle size distribution of the inhaled droplets generated with distilled water and two perfluorocarbons (PFCs). Different experiments were performed with driving pressures of 1⁻3 bar for each compound. An Aerodynamic Particle Sizer was used to measure the aerodynamic diameter (Da), the mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD). The results showed that both prototypes produced heterodisperse aerosols with Da mean values in all cases below 5 m. The initial experiments with distilled water showed MMAD values lower than 9 m and up to 15 m with prototype 1 and prototype 2, respectively. Regarding the PFCs, relatively uniform MMAD values close to 12 m were achieved. The air delivery with outer lumens of prototype 1 presented more suitable mass distribution for the generation and delivery of a uniform aerosol than the two half-circular ring geometry proposed in the prototype 2. | es_ES |
dc.description.sponsorship | Funding: This work has been supported by Consolidated Groups from the Basque Government and Fundation
VITAL Fundazioa. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | MDPI | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es/ | * |
dc.subject | aerodynamic particle sizer | es_ES |
dc.subject | aerosol | es_ES |
dc.subject | drug delivery | es_ES |
dc.subject | nebulizer | es_ES |
dc.subject | particle size distribution | es_ES |
dc.title | Experimental Evaluation of Perfluorocarbon Aerosol Generation with Two Novel Nebulizer Prototypes | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.holder | This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0). | es_ES |
dc.rights.holder | Atribución 3.0 España | * |
dc.relation.publisherversion | https://www.mdpi.com/1999-4923/11/1/19 | es_ES |
dc.identifier.doi | 10.3390/pharmaceutics11010019 | |
dc.departamentoes | Ciencias y Técnicas de la Navegación, Máquinas y Construcciones Navales | es_ES |
dc.departamentoes | Ingeniería nuclear y mecánica de fluidos | es_ES |
dc.departamentoes | Química física | es_ES |
dc.departamentoeu | Ingeniaritza nuklearra eta jariakinen mekanika | es_ES |
dc.departamentoeu | Itsasketa zientziak eta teknikak | es_ES |
dc.departamentoeu | Kimika fisikoa | es_ES |