Show simple item record

dc.contributor.authorFernández Pérez, Igor ORCID
dc.contributor.authorAlberro Astarbe, Mikel
dc.contributor.authorMontalbán Sánchez, Jon ORCID
dc.contributor.authorArrinda Sanzberro, Amaia
dc.contributor.authorAngulo Pita, Itziar ORCID
dc.contributor.authorDe la Vega Moreno, David ORCID
dc.date.accessioned2024-01-12T18:13:55Z
dc.date.available2024-01-12T18:13:55Z
dc.date.issued2019-06-05
dc.identifier.citationMeasurement 145 : 519-524 (2019)es_ES
dc.identifier.issn0263-2241
dc.identifier.urihttp://hdl.handle.net/10810/63936
dc.description.abstract[EN] Voltage measurements in the frequency range from 10 kHz to 500 kHz are used to quantify the level of the Narrow Band Power Line Communication transmitted signals, the noise and the non-intentional conducted emissions generated by the devices connected to the Low Voltage grid. Considering that the voltage levels within this frequency range are very small if compared to measurements below 2 kHz, measuring equipment of higher precision is needed, but existing standards do not currently cover this frequency band. In this paper, a voltage adapter with improved performance at the 10 kHz–500 kHz frequency range for field measurements in LV networks is presented. Moreover, a measurement setup and methodology for the frequency-dependent characterization of this type of voltage adapters is described, which is used to demonstrate the outperformance of the designed probe with respect to four commercial devices.es_ES
dc.description.sponsorshipThis work has been financially supported in part by the Basque Government (Elkartek program and IT-683-13).es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectfrequency responsees_ES
dc.subjectlow voltage networkses_ES
dc.subjectNarrowBand power line communicationses_ES
dc.subjectpower system measurementses_ES
dc.subjectvoltage measurementes_ES
dc.subjectvoltage probeses_ES
dc.titleA new voltage probe with improved performance at the 10 kHz–500 kHz frequency range for field measurements in LV networkses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.holder© 2019 Elsevier Ltd., under CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)es_ES
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/abs/pii/S0263224119305585es_ES
dc.identifier.doi10.1016/j.measurement.2019.05.106
dc.departamentoesIngeniería de comunicacioneses_ES
dc.departamentoesMatemática aplicadaes_ES
dc.departamentoesTecnología electrónicaes_ES
dc.departamentoeuKomunikazioen ingeniaritzaes_ES
dc.departamentoeuMatematika aplikatuaes_ES
dc.departamentoeuTeknologia elektronikoaes_ES


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

© 2019 Elsevier Ltd., under CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
Except where otherwise noted, this item's license is described as © 2019 Elsevier Ltd., under CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)