Show simple item record

dc.contributor.authorVlietstra, Nynke
dc.contributor.authorShan, Juan
dc.contributor.authorvan Wees, Bart J.
dc.contributor.authorIsasa Gabilondo, Miren
dc.contributor.authorCasanova Fernández, Félix
dc.contributor.authorBen Youssef, J.
dc.date.accessioned2024-02-08T07:55:21Z
dc.date.available2024-02-08T07:55:21Z
dc.date.issued2014-11-26
dc.identifier.citationPhysical Review B 90(17) : (2014) // Article ID 174436es_ES
dc.identifier.issn2469-9969
dc.identifier.issn2469-9950
dc.identifier.urihttp://hdl.handle.net/10810/64854
dc.description.abstractThe spin-Seebeck effect (SSE) in platinum (Pt) and tantalum (Ta) on yttrium iron garnet has been investigated by both externally heating the sample (using an on-chip Pt heater on top of the device) and by current-induced heating. For SSE measurements, external heating is the most common method to obtain clear signals. Here we show that also by current-induced heating it is possible to directly observe the SSE, separate from the also present spin-Hall magnetoresistance (SMR) signal, by using a lock-in detection technique. Using this measurement technique, the presence of additional second-order signals at low applied magnetic fields and high heating currents is revealed. These signals are caused by current-induced magnetic fields (Oersted fields) generated by the used ac current, resulting in dynamic SMR signals.es_ES
dc.description.sponsorshipThis work is supported by NanoNextNL, a micro and nanotechnology consortium of the Government of the Netherlands and 130 partners, by the Marie Curie Actions (Grant 256470-ITAMOSCINOM), the Basque Government (PhD fellowship BFI-2011-106), by NanoLab NL and by the Zernike Institute for Advanced Materials (Dieptestrategie program).
dc.language.isoenges_ES
dc.publisherAmerical Physical Societyes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectspin Hall magnetoresistancees_ES
dc.subjectspin-Seebeck effectes_ES
dc.titleSimultaneous detection of the spin-Hall magnetoresistance and the spin-Seebeck effect in platinum and tantalum on yttrium iron garnetes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.holder© 2014 American Physical Societyes_ES
dc.relation.publisherversionhttps://journals.aps.org/prb/abstract/10.1103/PhysRevB.90.174436es_ES
dc.identifier.doi10.1103/PhysRevB.90.174436
dc.departamentoesFísicaes_ES
dc.departamentoeuFisikaes_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record